Which of the following make small-volume ultrasonic drug delivery systems different from their large-volume counterparts?

1. They do not use a couplant compartment.
2. Drugs are placed directly on the transducer.
3. Battery power is available on some units.
4. Patient flow, not a blower, carries the aerosol.
a. 2 and 4 only
b. 3 and 4 only
c. 1, 2, and 3 only
d. 1, 2, 3, and 4

ANS: D
Unlike the larger units, some of these systems do not use a couplant compartment; the medication is placed directly into the manifold on top of the transducer. The transducer is connected by ca-ble to a power source, often battery-powered to increase portability. These devices have no blower; the patient's inspiratory flow draws the aerosol from the nebulizer into the lung.

Health Professions

You might also like to view...

The spleen (yin) channel is paired with the _____ (yang) channel

a. small intestine b. large intestine c. stomach d. heart

Health Professions

You are passively stretching the hip flexors of a patient in the position of prone hip extension and knee flexion

You later note that the patient demonstrates greater hip extension passive range of motion (PROM) when you allow the knee to be straight during the stretching procedure. The reason for the improved hip extension PROM may best be explained by ____________________. a. elimination of active insufficiency that occurred during the original position b. elimination of passive insufficiency that occurred during the original position c. elimination of both active and passive insufficiency that occurred during the original position d. activation of passive insufficiency that occurred in the second position