A heated air-entrainment large-volume jet nebulizer needs to be set up for a patient. In addition to the nebulizer, which of the following pieces of equipment are needed?

1. Heating device
2. Tracheostomy collar
3. Thermometer
4. Aerosol mask
5. Drain bag
6. Oxygen tubing
7. Corrugated tubing
a. 1, 2, 5, and 7 c. 3, 4, 5, and 6
b. 4 and 7 d. 1, 3, 4, 5, and 7

ANS: D
Because the patient is not intubated, an aerosol mask needs to be used with a nebulizer that has a heating device. Corrugated tubing with a thermometer and a drain bag in-line to collect the rain out are also needed. Oxygen tubing is not used with large-volume nebulizers.

Health Professions

You might also like to view...

You have been called to a hunting camp for a patient with a severe localized cold injury to his hand and fingers. The patient is suffering no life-threatening conditions and you elect to rewarm the affected areas. Which one of the following would be appropriate for this patient?

A) Immerse the hand and fingers in water no hotter than 120°F. B) Place the hand lower than the heart after rewarming is complete. C) Do not stir the water while the hand is submerged to decrease risk for injury. D) Thaw and rewarm the tissue as quickly as possible.

Health Professions

What do the components of a liquid O2 bulk storage tank include?

1. Inner and outer steel shells, separated by a vacuum 2. Safety system that vents O2 if warming occurs 3. Vaporizer system that converts liquid O2 to gas 4. Pressure-reducing valves to lower pressure to 50 psig a. 1, 2, and 3 only b. 2 and 4 only c. 1, 2, 3, and 4 d. 3 and 4 only

Health Professions