The flow-volume loop below is representative of which of the following conditions?

a. System leak
b. Intrinsic PEEP
c. Inadequate flow
d. Active exhalation

ANS: B
The expiratory flow in this loop does not return to zero. This shows that auto-PEEP or intrinsic PEEP is present.