The flow-volume loop below is representative of which of the following conditions?
a. System leak
b. Intrinsic PEEP
c. Inadequate flow
d. Active exhalation
ANS: B
The expiratory flow in this loop does not return to zero. This shows that auto-PEEP or intrinsic PEEP is present.
You might also like to view...
Describe what steps should be taken to prevent a possible airway obstruction from occurring during the try-in of the crown.
A 35-year-old female presents with a negative medical history. The treatment plan for today is to have a crown placed on tooth number 3. The crown has been delivered from the lab and the dentist is preparing to try the crown on the tooth. What will be an ideal response?
The medical specialty that focuses on disorders, injuries, and diseases of the muscular and skeletal systems is ________.
Fill in the blank(s) with the appropriate word(s).